PASS/EQUIPWorking with PASS/EQUIPData input → Rigid link


3.84. Rigid link


The component allows the two endpoints of the device to be rigidly connected at the level of a beam finite element model, by visually forming a rectilinear area of the given section.

Fig. 1. Rigid link

The component is attached to the end of the shell or nozzle, or to the joining pad, or to the saddle support.

The other end area shall be selected from the list of available related components.